  Datasheet File OCR Text:
  for more information, please visit the product page. ????????? ?????????????????? cui .com 02/23/2017 1 of 5 series : psk-10b description: ac-dc power supply model output voltage output current output power ripple and noise 1 effciency (vdc) max (a) max (w) typ (mvp-p) typ (%) psk-10b-s5 5 2 10 100 79 psk-10b-s9 9 1.1 10 100 82.14 PSK-10B-S12 12 0.85 10.2 120 82.32 psk-10b-s15 15 0.7 10.5 150 82.49 psk-10b-s24 24 0.45 10.8 240 82.49 notes: 1. at full load, nominal input, 20 mhz bandwidth oscilloscope, output terminated with 10 f electrolytic and 0.1 f ceramic capacitors. 2. all specifcations are measured at ta=25c, nominal input voltage, and 75% rated output load unless otherwise specifed. features ? up to 10 w continuous power ? universal input: 85~264 vac ? compact encapsulated design ? single output from 5 vdc ~ 24 vdc ? short circuit, over voltage protection, over current protection ? 4000 vac isolation ? no load power consumption <100 mw part number key base number psk-10b - s xx output voltage date page
for more information, please visit the product page. ?????????????????? cui .com date 02/23/2017 page 2 of 5 cui inc series : psk-10b description: ac-dc power supply input parameter conditions/description min typ max units voltage 85 120 264 370 vac vdc frequency 47 63 hz current 0.3 a inrush current at 240 vac, 25c, cold start 50 a leakage current 0.25 ma no load power consumption 0.10 w output parameter conditions/description min typ max units capacitive load 5 vdc output model 9 vdc output model 12 vdc output model 15 vdc output model 24 vdc output model 2,000 1,100 850 700 450 f f f f f initial set point accuracy at full load, 25c 2 % line regulation high line to low line at full load 0.5 % load regulation 10%~100% load 3 % hold-up time at 115 vac 12 ms switching frequency at 115 vac, full load at 230 vac, full load 85 65 khz khz temperature coeffcient 0.05 %/c protections parameter conditions/description min typ max units over voltage protection hiccup, auto recovery over current protection 110 % short circuit protection hiccup, auto recovery safety & compliance parameter conditions/description min typ max units isolation voltage input to output 4,000 vac safety approvals iec62368-1/60950-1, en62368-1/60950-1, ul62368-1/60950-1 safety class class ii emi/emc en 55032 class b, fcc part 15 class b, en 61000- 6-3, en 61000-3-2, en 61000-3-3, en 55024, en 61204-3, en 61000-6-1 mtbf as per mil-std-217f, at 115 vac, 25c, gb 300,000 hours life time at 40c, 75% load 3 years rohs 2011/65/eu environmental parameter conditions/description min typ max units operating temperature see derating curve -25 70 c storage temperature -40 85 c operating humidity non-condensing 93 % operating altitude 3000 m
for more information, please visit the product page. ?????????????????? cui .com date 02/23/2017 page 3 of 5 cui inc series : psk-10b description: ac-dc power supply solderability parameter conditions/description min typ max units wave soldering see wave soldering profle 260 c t emperature ( c) t ime (seconds) notes: 1. soldering materials: sn/cu/ni 2. ramp up rate during preheat: 1.4c/s (from 50c to 100c) 3. soaking temperature: 0.5c/s (from 100c to 130c), 6020 seconds 4. peak temperature: 260c, above 250c for 3~6 seconds 5. ramp down rate during cooling: -10c/s (from 260c to 150c) mechanical parameter conditions/description min typ max units dimensions 2.000 x 1.000 x 0.809 (50.80 x 25.40 x 20.55 mm) inch weight 45 g cooling natural convection mechanical drawing pin connections pin function 1 acn 2 acl 3 +vout 4 -vout 2.54 10.1 6 0.800 0.10 0 1.80 04 5.72 20.3 2 0.40 0 2.00 05 0.80 1.000 25.4 0 0.80 9 20.5 5 1.00 0.03 9 0.23 66 .0 0 2 3 4 1 units: inch [mm] tolerance: x.xxx = 0.020 [0.50]
for more information, please visit the product page. ?????????????????? cui .com date 02/23/2017 page 4 of 5 cui inc series : psk-10b description: ac-dc power supply derating curve output power vs. ambient temperature (natural convention) ambient t emper ature (c) load (% ) -25 50 75 100 25 -15 15 45 65 -5 52 53 55 57 5 0 0 efficiency curves 5 vdc output effciency curve (at 25c) 85 vac 115 vac 230 vac 264 vac 10 current load (% ) 20 30 40 50 60 70 80 90 100 55.0 60.0 65.0 70.0 75.0 80.0 85.0 efficiency (% ) 9 vdc output effciency curve (at 25c) 85 vac 115 vac 230 vac 264 vac 10 current load (% ) 20 30 40 50 60 70 80 90 100 55.0 60.0 65.0 70.0 75.0 80.0 85.0 efficiency (% ) 90.0 12 vdc output effciency curve (at 25c) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 efficiency (% ) 10 current load (% ) 20 30 40 50 60 70 80 90 100 85 vac 115 vac 230 vac 264 vac 90.0 15 vdc output effciency curve (at 25c) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 efficiency (% ) 10 current load (% ) 20 30 40 50 60 70 80 90 100 85 vac 115 vac 230 vac 264 vac 90.0 24 vdc output effciency curve (at 25c) 55.0 60.0 65.0 70.0 75.0 80.0 85.0 efficiency (% ) 10 current load (% ) 20 30 40 50 60 70 80 90 100 85 vac 115 vac 230 vac 264 vac 90.0
for more information, please visit the product page. ????????? date 02/23/2017 page 5 of 5 cui inc series : psk-10b description: ac-dc power supply cui offers a two (2) year limited warranty. complete warranty information is listed on our website. cui reserves the right to make changes to the product at any time without notice. information provided by cui is believed to be accurate and reliable. however, no responsibility is assumed by cui for its use, nor for any infringements of patents or other rights of third parties which may result from its use. cui products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. a critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. headquarters 20050 sw 112th ave. tualatin, or 97062 800.275.4899 fax 503.612.2383 cui .com techsupport@cui.com rev. description date 1.0 initial release 02/23/2017 the revision history provided is for informational purposes only and is believed to be accurate. revision history


▲Up To Search▲   

 
Price & Availability of PSK-10B-S12

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X